Alarm Policy settingsΒΆ

Individual Alarm Policy settings allow granular customization of what, when, and how Alarms and Events are reported.

The following settings can be accessed from the Admin > Alarm Monitor > Alarm Policies view:

Status

Sets the Alarm Policy to one of three states:

Setting

Generates Events

Alarm Monitor

Stored in Database

Notifications by Profile(s)

Active

Yes

Yes

Yes

Yes

Store

Yes

No

Yes

Yes

Inactive

No

No

No

No

Weight

Assigns each Event generated by the Alarm Policy a numerical weight that is used to calculate the severity reported in the Alarm Monitor views

Event timeout

Sets the number of seconds the system will wait when aggregating observations meeting the same criteria as a single Event

Hint

Setting nonessential Alarm Policies to Store or Inactive can filter out Events that do not require visibility. This can reduce the number of Alarms being reported (and stored) in the Alarm Monitor views.